Products

Current position: Home >  Sensor  >  Microwave sensor > 

Microwave sensor

ZSY humidity and density sensor based on the resonator,Use the characteristic that intracavitary microwave attenuation and phase difference of analyte depends on cavity material,We developed a kind of microwave sensor can achieve ultra high speed and high precision measuring,this sensors Can be used to measure solid, liquid and gas material,Even the bad environment can also be a good measure.

Return list
-Main features-
  • High Speed Standard – 10.000sec;

  • Ultra High Speed Option  – 100.000sec;

  • Outstanding Accuracy;

  • Contact Free Measurement;

  • Various Interfaces;

  • No Nuclear Radiation;

  • Maintenance Free;

  • Easy Integration;

  • Rugged Housing;

  • Custom Design;

-Application area-

Used for measure humidity or residual moisture, density , tiny foreign body recognition, etc

-Technical specifications-
ParameterValue 
Output Interface:
digitalRS232 (max. 460.8 kbit/s) or RS485 (max. 921.6 kbit/s) or RS232 and CAN V2.0B (max 1Mbit/s) or Ethernet and (RS32 or RS485)
analog4…20 mA (≤ 500 Ω load) or 0…10 V
Synchronization input2,4 – 5 V (CMOS, TTL)
Logic outputprogrammed functions, NPN: 100 mA max; 40 V max for output
Power supply, V9 …36
Power consumption, W1,5..2
Environment resistance: 
Enclosure ratingIP67 ( for the sensors with cable connector only)
Vibration20g/10…1000Hz, 6 hours, for each of XYZ axes
Shock30 g / 6 ms
Operation temperature, °С-10…+60, (-30…+60 for the sensors with in-built heater),
(-30…+120 for the sensors with in-built heater and air cooling housing)
Permissible ambient light, lx>30000
Relative humidity5-95% (no condensation)
Storage temperature, °С-20…+70
Housing materialaluminum

Note: parameters can be changed for a specific task.

ZLDS100-R-425101525305010025050075010001250
Measurement range, mm425101525305010025050075010001250
Base distance X, mm39151515, 25, 6015, 30, 6525, 45, 8035, 55, 9545, 65, 10560, 90, 14080125145245260
Linearity, %±0.05 of the range±0.1
Resolution, %0.01 of the range (for the digital output only)0.02
Temperature drift0,02% of the range/°С
Max. measurement frequency, Hz9400
Light source:red semiconductor laser, 660 nm wavelength
or UV semiconductor laser 405/450 nm wavelength (BLUE version)
modelZLDS100
output power≤0,2≤5 mW
laser safety Class13R (IEC60825-1)
modelZLDS100L
output power≤0,95 mW
laser safety Class2 (IEC60825-1)
modelZLDS100Р
output power≤20 mW
laser safety Class3В (IEC60825-1)
Weight (without cable), gram100















ZLDS100/HS-X-2X-5X-10X-15X-25X-30X-50X-100X-250X-500X-750
Base distance X, mm151515, 25, 6015, 30, 6525, 45, 8035, 55, 9545, 65, 10560, 90, 14080125145
Measurement range, mm251015253050100250500750
Max. measurement frequency, kHz70
Linearity, %±0.1 (70 kHz),  of the range
Resolution, %0.01 (70 kHz),  of the range
Temperature drift0,02% of the range/°С
Light sourcered semiconductor laser, 660 nm wavelength or
UV semiconductor laser 405/450 nm wavelength (BLUE version)
Output power≤4.8 mW≤20 mW ≤80 mW
Laser safety Class3R (IEC/EN 60825-1:2014)3В  (IEC/EN 60825-1:2014)
Weight (without cable), gram110
ZLDS100RD-375±250745±500440±250310±100355±12545±15
Base distance X, mm12524519021023030
Measurement range, mm500100050020025030
Linearity, % of the range±0.05±0.03±0.05
Resolution, % of the range0,01 (for the digital output only)
Temperature drift0,02% of the range / °С
Max. measurement frequency, Hz9400700009400
Light sourcered semiconductor laser, 660 nm wavelength
Output power, mW<20<80<1
Laser safety class (IEC/EN 60825-1:2014)3В2
Laser spot shapeellipticround
Laser spot size "beginning-middle-end of the range", mm1,7х3- 0,16х0,2- 3х51,6х2,5- 0,5х0,8- 1,6х3,50,9-1-0,90,8-0,7-0,60,8-0,7-0,50,06-0,025-0,06
ZLDS101-X-10X-30X-40X-100X-250X-500X-600X-1000X-1000X-1500X-2000X-2500
Base distance X, мм230300330500230300, 10002303801300390410420
Measurement range,  mm10304010025050060010001000150020002500
Linearity, %±0.1 of the range
Resolution, %0.01 of the range (for the digital output only)0.02
Temperature drift0,02% of the range/°С
Max. measurement frequency, Hz9400 or 70000
Light sourcered semiconductor laser, 660 nm wavelength or
UV semiconductor laser 405/450 nm wavelength (BLUE version)
output power≤4,8 mW≤20 mW
laser safety Class3R (IEC60825-1)3В  (IEC60825-1)
Weight (without cable), gram500
ZLDS102-25-5045-10065-250105-500
Base distance X, mm254565105
Measurement range, mm50100250500
Linearity, %±0.1 of the range
Resolution, %0.02 of the range
Temperature drift0,02% of the range/°С
Max. sampling frequency, Hz2000
Light sourcered semiconductor laser, 660 nm wavelength
Output power, mW≤0,95 mW
Laser safety Class2  (IEC60825-1)
Weight (without cable), gram60
ZLDS103-20/1020/2530/5055/10065/250105/500
Base distance X, mm2020305565105
Measurement range, mm102550100250500
Linearity, %±0,05 of the range±0,1
Resolution, %0,01 of the range0,02
Temperature drift0,02% of the range/°С
Max. sampling frequency, Hz9400
Light sourcered semiconductor laser, 660 nm wavelength or
UV semiconductor laser 405 nm wavelength (BLUE version)
Output power, mW≤1
Laser safety Class2  (IEC60825-1)
Weight (without cable), gram40
-Measuring principle-


Model

Microwave sensor

Range

0%-60%

Accuracy

0.1%

Digital output

Ethernet

Analog output

4-20mA

Power supply

22-30VDC

Operating current

280mA@24VDC

Working temperature

0-80℃,Probe:0-100℃

Weight

about 1.55kg, depending on the resonator version



◆Technical specifications can be customized according to customer requirements
◆
We reserve the right to change the specifications without notice.



-Industry solutions-


-Successful case-


-Mounting dimensions-

Please contact us to get more informations.

-Related products-
About us
Solutions
Products
Contact us
Contact number

0044 2084323088

Email


©2005-2024 ZSY Group Ltd. All rights reserved.